6.4 Engraving Machine Macro 400HZ
6.4 Engraving Machine Macro 400HZ
X1 controls forward rotation start/stop, X2 controls multi-speed terminal 1, X3 controls multi-speed terminal 2, X4 controls multi-speed terminal 3. The combination of three terminals is as follows:
Speed | Corresponding Frequency | Multi-Speed Terminal 1 | Multi-Speed Terminal 2 | Multi-Speed Terminal 3 |
---|---|---|---|---|
0 | 0Hz | OFF | OFF | OFF |
1 | 100Hz | ON | OFF | OFF |
2 | 150Hz | OFF | ON | OFF |
3 | 200Hz | ON | ON | OFF |
4 | 250Hz | OFF | OFF | ON |
5 | 300Hz | ON | OFF | ON |
6 | 350Hz | OFF | ON | ON |
7 | 400Hz | ON | ON | ON |
Explore these documents for more information: