5.12 Pb Group Swing Frequency, Fixed Length, and Counting
5.12 Pb Group Swing Frequency, Fixed Length, and Counting
ℹ️
Inverter Parameter Attribute Explanation
✳️: Indicates that the setting value of this parameter cannot be changed when the inverter is in a running state;
❎: Indicates that the value of this parameter is an actual detection record value and cannot be changed.
Pb Group: Swing Frequency, Fixed Length, and Counting
Function Code | Name | Setting Range | Factory Value | Attribute | DEC Address |
---|---|---|---|---|---|
Pb-00 | Swing Frequency Setting Method | 0: Relative to Center Frequency 1: Relative to Maximum Frequency |
0 | ✅ | 64256 |
Pb-01 | Swing Amplitude | 0.0~100.0% | 0.0% | ✅ | 64257 |
Pb-02 | Jump Frequency Amplitude | 0.0~50.0% | 0.0% | ✅ | 64258 |
Pb-03 | Swing Frequency Period | 0.1~3000.0s | 10.0s | ✅ | 64259 |
Pb-04 | Rise Time of Swing Triangle Wave | 0.1~100.0% | 50.0% | ✅ | 64260 |
Pb-05 | Set Length | 0~65535m | 1000m | ✅ | 64261 |
Pb-06 | Actual Length | 0~65535m | 0m | ✅ | 64262 |
Pb-07 | Pulses per Meter | 0.1~6553.5 | 100.0 | ✅ | 64263 |
Pb-08 | Set Count Value | 1~65535 | 1000 | ✅ | 64264 |
Pb-09 | Specified Count Value | 1~65535 | 1000 | ✅ | 64265 |