5.18 U0 Group Parameter Monitoring
5.18 U0 Group Parameter Monitoring
ℹ️
Variable Frequency Drive Parameter Attribute Explanation
U0 Group: Parameter Monitoring
Function Code | Name | Setting Range | Factory Value | Attribute | DEC Address |
---|---|---|---|---|---|
U0-00 | Running Frequency (Hz) | – | 0.01Hz | ❎ | 28672 |
U0-01 | Set Frequency (Hz) | – | 0.01Hz | ❎ | 28673 |
U0-02 | Bus Voltage (V) | – | 0.1V | ❎ | 28674 |
U0-03 | Output Voltage (V) | – | 1V | ❎ | 28675 |
U0-04 | Output Current (A) | – | 0.01A | ❎ | 28676 |
U0-05 | Output Power (Kw) | – | 0.1Kw | ❎ | 28677 |
U0-06 | Output Torque (%) | – | 0.1% | ❎ | 28678 |
U0-07 | X Input Status | – | 1 | ❎ | 28679 |
U0-08 | Y Output Status | – | 1 | ❎ | 28680 |
U0-09 | AI1 Voltage (V) | – | 0.01V | ❎ | 28681 |
U0-10 | AI2 Voltage (V) | – | 0.01V | ❎ | 28682 |
U0-11 | AI3 Panel Potentiometer Voltage (V) | – | 0.01V | ❎ | 28683 |
U0-12 | Counter Value | – | 1 | ❎ | 28684 |
U0-13 | Length Value | – | 1 | ❎ | 28685 |
U0-14 | Load Speed Display | – | 1 | ❎ | 28686 |
U0-15 | PID Set (Dimensionless) PID Set Pressure Value (Water Supply Activation) |
– | 1 0.01kg |
❎ | 28687 |
U0-16 | PID Feedback (Dimensionless) PID Feedback Set Pressure Value (Water Supply Activation) |
– | 1 0.01kg |
❎ | 28688 |
U0-17 | PLC Phase | – | 1 | ❎ | 28689 |
U0-18 | HDI Input Pulse Frequency (Hz) | – | 0.01kHz | ❎ | 28690 |
U0-19 | Feedback Speed (Unit 0.1Hz) | – | 0.1Hz | ❎ | 28691 |
U0-20 | Remaining Operating Time | – | 0.1Min | ❎ | 28692 |
U0-21 | AI1 Pre-Calibration Voltage | – | 0.001V | ❎ | 28693 |
U0-22 | AI2 Pre-Calibration Voltage | – | 0.001V | ❎ | 28694 |
U0-23 | Panel Potentiometer Pre-Calibration Voltage | – | 0.001V | ❎ | 28695 |
U0-24 | Line Speed | – | 1m/Min | ❎ | 28695 |
U0-25 | Current Power-On Time | – | 1Min | ❎ | 28697 |
U0-26 | Current Operating Time | – | 0.1Min | ❎ | 28698 |
U0-27 | HDI Input Pulse Frequency | – | 1Hz | ❎ | 28699 |
U0-28 | Communication Set Value | – | 0.01% | ❎ | 28700 |
U0-30 | Main Frequency X Display | – | 0.01Hz | ❎ | 28702 |
U0-31 | Auxiliary Frequency Y Display | – | 0.01Hz | ❎ | 28703 |
U0-32 | View Any Memory Address Value | – | 1 | ❎ | 28704 |
U0-35 | Target Torque (%) | – | 0.1% | ❎ | 28707 |
U0-36 | Current Working Auxiliary Pump Number | – | 1 | ❎ | 28708 |
U0-37 | Power Factor Angle | – | 0.1° | ❎ | 28709 |
U0-39 | Reserved | – | 1V | ❎ | 28710 |
U0-40 | Reserved | – | 1V | ❎ | 28711 |
U0-41 | X Input Status Intuitive Display | – | 1 | ❎ | 28712 |
U0-42 | Y Input Status Intuitive Display | – | 1 | ❎ | 28713 |
U0-43 | X Function Status Intuitive Display 1 | – | 1 | ❎ | 28714 |
U0-44 | X Function Status Intuitive Display 2 | – | 1 | ❎ | 28715 |
U0-45 | Fault Information | – | 1 | ❎ | 28716 |
U0-59 | Set Frequency (%) | – | 0.01% | ❎ | 28717 |
U0-60 | Running Frequency (%) | – | 0.01% | ❎ | 28731 |
U0-61 | Inverter Status | – | 1 | ❎ | 28733 |
U0-62 | Current Fault Code | – | 1 | ❎ | 28734 |
U0-65 | Torque Limit | – | 0.1% | ❎ | 28737 |