5.13 Pc Group Multi-segment Speed Instructions and Simple PLC
5.13 Pc Group Multi-segment Speed Instructions and Simple PLC
ℹ️
Inverter Parameter Attribute Explanation
✳️: Indicates that the setting value of this parameter cannot be changed when the inverter is in a running state;
❎: Indicates that the value of this parameter is an actual detection record value and cannot be changed.
Pc Group: Multi-segment Speed Instructions and Simple PLC
Function Code | Name | Setting Range | Factory Value | Attribute | DEC Address |
---|---|---|---|---|---|
Pc-00 | Multi-segment Instruction 0 | -100.0%~100.0% | 0.0% | ✅ | 64512 |
Pc-01 | Multi-segment Instruction 1 | -100.0%~100.0% | 0.0% | ✅ | 64513 |
Pc-02 | Multi-segment Instruction 2 | -100.0%~100.0% | 0.0% | ✅ | 64514 |
Pc-03 | Multi-segment Instruction 3 | -100.0%~100.0% | 0.0% | ✅ | 64515 |
Pc-04 | Multi-segment Instruction 4 | -100.0%~100.0% | 0.0% | ✅ | 64516 |
Pc-05 | Multi-segment Instruction 5 | -100.0%~100.0% | 0.0% | ✅ | 64517 |
Pc-06 | Multi-segment Instruction 6 | -100.0%~100.0% | 0.0% | ✅ | 64518 |
Pc-07 | Multi-segment Instruction 7 | -100.0%~100.0% | 0.0% | ✅ | 64519 |
Pc-16 | Simple PLC Operating Mode | 0: Stop after Single Run 1: Maintain Final Value after Single Run 2: Continuous Loop |
0 | ✅ | 64528 |
Pc-17 | Simple PLC Power-off Memory Selection | Units: Power-off Memory Selection 0: No Power-off Memory 1: Power-off Memory Tens: Stop Memory Selection 0: No Stop Memory 1: Stop Memory |
00 | ✅ | 64529 |
Pc-18 | Simple PLC-0 Segment Running Time | 0.0s(h)~6553.5s(h) | 0.0s(h) | ✅ | 64530 |
Pc-19 | Simple PLC-0 Segment Acceleration/Deceleration Time Selection | 0~3 | 0 | ✅ | 64531 |
Pc-20 | Simple PLC-1 Segment Running Time | 0.0s(h)~6553.5s(h) | 0.0s(h) | ✅ | 64532 |
Pc-21 | Simple PLC-1 Segment Acceleration/Deceleration Time Selection | 0~3 | 0 | ✅ | 64533 |
Pc-22 | Simple PLC-2 Segment Running Time | 0.0s(h)~6553.5s(h) | 0.0s(h) | ✅ | 64534 |
Pc-23 | Simple PLC-2 Segment Acceleration/Deceleration Time Selection | 0~3 | 0 | ✅ | 64535 |
Pc-24 | Simple PLC-3 Segment Running Time | 0.0s(h)~6553.5s(h) | 0.0s(h) | ✅ | 64536 |
Pc-25 | Simple PLC-3 Segment Acceleration/Deceleration Time Selection | 0~3 | 0 | ✅ | 64537 |
Pc-26 | Simple PLC-4 Segment Running Time | 0.0s(h)~6553.5s(h) | 0.0s(h) | ✅ | 64538 |
Pc-27 | Simple PLC-4 Segment Acceleration/Deceleration Time Selection | 0~3 | 0 | ✅ | 64539 |
Pc-28 | Simple PLC-5 Segment Running Time | 0.0s(h)~6553.5s(h) | 0.0s(h) | ✅ | 64540 |
Pc-29 | Simple PLC-5 Segment Acceleration/Deceleration Time Selection | 0~3 | 0 | ✅ | 64541 |
Pc-30 | Simple PLC-6 Segment Running Time | 0.0s(h)~6553.5s(h) | 0.0s(h) | ✅ | 64542 |
Pc-31 | Simple PLC-6 Segment Acceleration/Deceleration Time Selection | 0~3 | 0 | ✅ | 64543 |
Pc-32 | Simple PLC-7 Segment Running Time | 0.0s(h)~6553.5s(h) | 0.0s(h) | ✅ | 64544 |
Pc-33 | Simple PLC-7 Segment Acceleration/Deceleration Time Selection | 0~3 | 0 | ✅ | 64545 |
Pc-50 | Simple PLC Running Time Unit | 0: s (seconds) 1: h (hours) |
0 | ✅ | 64562 |
Pc-51 | Multi-segment Instruction 0 Setting Mode | 0: Set by Function Code PC-00 1: AI1 2: AI2 3: AI3 External Keyboard Potentiometer 4: HDI Input Pulse 5: PID 6: Preset Frequency (P0-08) Setting, UP/DOWN Can Be Modified |
0 | ✅ | 64563 |