5.2 P1 Group Motor Parameters
5.2 P1 Group Motor Parameters
ℹ️
Inverter Parameter Attribute Description
✅: Indicates that the parameter setting value can be changed when the inverter is in both stopped and running states.
✳️: Indicates that the parameter setting value cannot be changed when the inverter is in a running state.
❎: Indicates that the parameter value is the actual measured recording value and cannot be changed.
P1 Group: Motor Parameters
Function Code | Name | Setting Range | Factory Value | Attribute | DEC Address |
---|---|---|---|---|---|
P1-00 | Motor Type Selection | 0: Ordinary Asynchronous Motor 1: Variable Frequency Asynchronous Motor 2: Permanent Magnet Synchronous Motor (Refer to Separate Manual) |
0 | ✳️ | 61696 |
P1-01 | Motor Rated Power | 0.1~1000KW | Model Dependent | ✳️ | 61697 |
P1-02 | Motor Rated Voltage | 1~380V | Model Dependent | ✳️ | 61698 |
P1-03 | Motor Rated Current | 0.01~100.00A | Model Dependent | ✳️ | 61699 |
P1-04 | Motor Rated Frequency | 0.01Hz~Maximum Frequency | Model Dependent | ✳️ | 61700 |
P1-05 | Motor Rated Speed | 1~65535rpm | Model Dependent | ✳️ | 61701 |
P1-10 | Asynchronous Motor No-load Current | 0.01~P1-03 | Tuning Parameter | ✳️ | 61706 |
P1-37 | Tuning Selection | 0: No Operation 1: Asynchronous Motor Static Tuning 2: Asynchronous Motor Full Tuning 3: Static Tuning 2 |
0 | ✳️ | 61733 |
Explore these documents to learn more.